<?xml version="1.0" standalone="yes"?>
<?xml-stylesheet type="text/xsl" href="..\..\XSLTemplates\ErrorsStyleSheet.xsl"?>
<Error>
<ErrorNumber>45031</ErrorNumber>
<ErrorFamily>Exposure Head Interface</ErrorFamily>
<ErrorMessage>
EHI: incorrect light level at start of edge detection - check if plate loaded is too large
</ErrorMessage>
<AppliesTo>
<UnnumberedList>
<ListItem><Text>Gravure</Text></ListItem>
<ListItem><Text>Japanese_Newspaper_OEM_Engine</Text></ListItem>
<ListItem><Text>Lotem_Quantum</Text></ListItem>
<ListItem><Text>Magnus_400</Text></ListItem>
<ListItem><Text>Magnus_800</Text></ListItem>
<ListItem><Text>Magnus_VLF</Text></ListItem>
<ListItem><Text>Slave_MCE_Firmware</Text></ListItem>
<ListItem><Text>Thermoflex</Text></ListItem>
<ListItem><Text>Think_Motion_Controller</Text></ListItem>
<ListItem><Text>Trendsetter_400/800</Text></ListItem>
<ListItem><Text>Trendsetter_NEWS</Text></ListItem>
<ListItem><Text>Trendsetter_Series_4</Text></ListItem>
</UnnumberedList>
</AppliesTo>
<ServiceInformation>
<DescriptionText><text>
At the beginning of the edge search, the focus servo has detected that
we are on the plate. The edge search algorithm backs up and tries again.
If we are still on the plate after EDGE_ATTEMPTS tries, this error
message is reported.
</text></DescriptionText>
</ServiceInformation>
<OperatorAction>
<DescriptionText><text>
Ensure the correct plate size is entered for the plate. If it is correct,
try selecting RESUME if it is available. If it is not correct, you must
cancel this job.
</text></DescriptionText>
</OperatorAction>
<Availability>
<DescriptionText><text>
This error is reported.
</text></DescriptionText>
</Availability>
<Cause>
The plate size (ssz) is too small.
</Cause>
<Cause>
Focus servo not working properly. If you have thermal head version 1.56 it is
easily possible to diagnose the exact problem by using the internal data
collection capabilities (see release notes or head diag0 information).
</Cause>
<Cause>
Head not installed properly.
</Cause>
<Cause>
Incorrect edge thresholds. Check the nvs parameters ONTHRESH and OFFTHRESH.
</Cause>
<LastModified>
03-Jul-2002
</LastModified>
<SeeAlso>
<UnnumberedList>
<Link><LinkAddress>../prm/ehi_head_onthresh.xml</LinkAddress><LinkTitle>PRM: head onthresh</LinkTitle></Link>
<Link><LinkAddress>../prm/ehi_head_offthresh.xml</LinkAddress><LinkTitle>PRM: head offthresh</LinkTitle></Link>
<Link><LinkAddress>../prm/ehi_head_diag0.xml</LinkAddress><LinkTitle>PRM: head diag0</LinkTitle></Link>
</UnnumberedList>
</SeeAlso>
<OtherLinks>
<Link><LinkAddress>..\..\ShowAllErrors.htm</LinkAddress><LinkTitle>Firmware 1 Error Index</LinkTitle></Link>
<Link><LinkAddress>..\..\ShowAllCommands.htm</LinkAddress><LinkTitle>Firmware 1 Command Index</LinkTitle></Link>
<Link><LinkAddress>..\..\ShowAllParameters.htm</LinkAddress><LinkTitle>Firmware 1 Parameter Index</LinkTitle></Link>
</OtherLinks>
<Updated>
Updated: Thu Jul 17 07:23:43 2008 PST
</Updated>
<Links>
</Links>
</Error>